ASAP 2460 & 2425
Surface Area & Porosimetry System
- Six independently operated analysis ports
- Long-duration Dewars and Micromeritics Isothermal Jackets
- The high-capacity Dewar
Analytical Versatility With Superior Throughput
Surface area and porosity are important physical properties that influence the quality and utility of many materials and products. Therefore it is critically important that these characteristics be accurately determined and controlled. Likewise, knowledge of surface area and especially porosity often are important properties in understanding the formation, structure, and potential application of many natural materials.
High Performance and High Sample Throughput The automated Micromeritics® ASAP® 2425 surface area and porosimetry system is designed to help busy laboratories expand their workflow while providing highly accurate and precise surface area and porosimetry data. High performance, versatile analysis, and sample preparation systems are included in the same instrument.
Features and Benefits:
- Fully automated analyses
- High throughput with six independent analysis stations
- Each analysis port has a dedicated analysis and Po pressure transducer
- Twelve independently controlled degas ports
- 疏散rate precisely regulated by a servo valve
- BET surface area measurements in as little as 1 hour
- Dosing options of maximum volume increment or dosing over specified pressure ranges
- Entered or calculated analysis temperature
- 平衡选项允许用户指定等温线的不同部分的平衡时间
- Low surface area option with five independent analysis ports
Specifications
ASAP 2425 Specifications
ASAP 2425 Specifications
电气
| 电压 | 100/115/230 VAC (± 10%) |
| Frequency | 50或60 Hz |
| Power | 800 VA, exclusive of vacuum pumps, which are powered separately |
环境
| 温度 | 10 to 30 °C operating, -10 to 55 °C storage or shipping |
| Humidity | Up to 90% relative (non-condensing) for instrument. |
Capacity
| Analysis System | 6 sample ports, each with a constantly monitored saturation pressure port |
| Degas System | 12 degas ports, each with independently controlled heating mantle |
Analysis System
| 歧管温度传感器 | Type: Platinum resistance device (RTD) Accuracy: ±0.10 °C by keyboard entry Stability: ±0.10 °C per month |
| 歧管压力传感器 | 范围: Vacuum to 950 mmHg operating: 1000 mmHg maximum 10 mmHg added for krypton option 1 mmHg for micropore optionResolution: 1000 mmHg Transducer: 0.01 mmHg 10 mmHg Transducer: 0.0001 mm 1 mmHg Transducer: 0.00001 mmAccuracy: 1000 mmHg Transducer: within 0.1% FS 10 mmHg tendducer1:在读取的0.15%以内 1 mmHg Transducer2 : within within 0.12% of reading |
| Sample Port Transducer and Po Port Transducers | 范围:0 to 950 mmHg Resolution: 0.01 mmHg Accuracy: ±0.1% Full Scale |
| Vacuum Gauge | Type: Thermocouple 范围:0.001 to 1 mmHg |
Physical
| Height | 159 cm (62.5 in.) |
| Width | 103 cm (40.5 in.) |
| Depth | 51厘米(20.2英寸) |
| Weight | 160 kg (350 lb) |
Vacuum System
| Nitrogen System Pumps | 2 oil-based pumps: 1 analysis, 1 degas 4 pumps (optional): 2 oil-free (1 analysis, 1 degas), 2 high vacuum (1 analysis, 1 degas) |
| Krypton & Micropore Pumps | 油基机械泵: 5 x 10-3 mmHg ultimate vacuum Oil-free and high vacuum pump: 3.8 x 10-9 mmHg ultimate vacuum3 |
Degas System
| Capacity | 12 degas ports |
| 真空控制 | Selectable target pressure controls switchover from restricted to unrestricted evacuation |
| 疏散 | Selectable evacuation rate from 1.0 to 50.0 mmHg/s |
| 歧管压力传感器 | 范围:0 to 950 mmHg Resolution: 0.01 mmHg Accuracy: ±0.1% Full Scale |
| Vacuum Transducer | Type: Thermocouple 范围:0.001 to 1 mmHg |
| 标题为回填气体 | User-selectable at dedicated port, typically nitrogen or helium |
| 温度Control | 温度范围:Ambient to 450 °C (Programmable) 温度Control: 1 ramp during evacuation phase, 5 additional selectable ramps during heating phase 选择:数字设置,从计算机增加1°C Accuracy: Deviation less than ±10 °C of set point at the sensing thermocouple embedded in the heating mantle |
Computer Requirements
Windows® 7 Professional or higher operating system recommended (64 bit)4 USB port5 Ethernet port (10 base T or 100 base T)
ASAP 2460 Specifications
ASAP 2460 Specifications
电气
| 电压 | 100/115/230 VAC (± 10%) |
| Frequency | 50或60 Hz |
| Power | 800 VA, exclusive of vacuum pumps, which are powered separately |
环境
| 温度 | 10 to 30 °C operating, -10 to 55 °C storage or shipping |
| Humidity | Up to 90% relative (non-condensing) for instrument. |
Capacity
| Analysis System | 2, 4, or 6 sample ports (for krypton analysis, one sample port is used for dosing), each with a constantly monitored saturation pressure port |
Analysis System
| 歧管温度传感器 | Type: Platinum resistance device (RTD) Accuracy: ±0.10 °C by keyboard entry Stability: ±0.10 °C per month |
| 歧管压力传感器 | 范围:0 to 950 mmHg operating: 1000 mmHg maximum 0 to 10 mmHg added for Krypton option Resolution: 1000-mmHg Transducer: 0.001 mmHg 10-mmHg Transducer1: 0.00001 mmHg 1-mmHg Transducer**: 0.000001 mmHg Accuracy: 1000-mmHg Transducer: within 0.15% of reading 10-mmHg Transducer1: within 0.15% of reading 1-mmHg Transducer2: within 0.12% of reading |
| Sample Port Transducer and Po Port Transducers | 范围:0 to 950 mmHg Resolution: 0.001 mmHg Accuracy: ±0.1% Full Scale |
| Vacuum Transducer | Type: Thermocouple 范围:0.001 to 1 mmHg |
Physical
| Height | 94 cm (37 in.) |
| Width | 38 cm (15 in.) |
| Depth | 59厘米(23英寸) |
| Weight | 54 kg (119 lb) |
Vacuum System
| Pumps3 | Nitrogen: Oil-sealed pump Krypton & enhanced micropore option: High-vacuum pump |
Computer Requirements:Windows® 7 Professional or higher operating system (64 bit)5,7 USB port6 Ethernet port (10 base T or 100 base T)
Includes nonlinearity, hysteresis, and non-repeatability.
1The 10-mmHg transducer is active only when performing krypton analyses
2The 1-mmHg transducer is presented only in the enhanced micropore option
3Oil-free and high vacuum pump: 3.8 × 10-9 mmHg ultimate vacuum4
4Ultimate vacuum measured by pump manufacturer according to Pneurop Standard 5608 Due to continuous improvements, specifications are subject to change without notice.
5For 21 CFR Part 11, Windows 10 Professional or Windows 10 Enterprise or higher is required.
6必须提供一个额外的USB端口。
7Not be installed on a network drive with shared access. Multiple users cannot operate the application at the same time.
Due to continuous improvements, specifications are subject to change without notice
Analysis System

- With six independently operated analysis ports, a new analysis can begin as soon as another is finished.
This provides an important advantage over many multiport instruments that require all samples to be
prepared or analyzed at the same time. - Long-duration Dewars and Micromeritics Isothermal Jackets1 assure a constant thermal profile along
the length of both the sample and saturation pressure (Po) tubes throughout extended analyses.
The Po value may be entered, or measured either continuously or at selected intervals. - The high-capacity Dewar also allows unattended analysis of high-resolution adsorption/desorption
isotherms that take much longer to complete because the system must equilibrate at each data point. - BET surface area analyses utilizing six parallel runs can be achieved in as little as 1 hour.
- A low surface area option that uses krypton as an adsorptive to measure total surface areas of 0.5 m2 or less is available. This option utilizes five of the six available ports. It also features a turbomolecular drag pump, which provides the high vacuum required for krypton analyses, and a 10 mmHg pressure transducer, which allows accurate, repeatable pressure resolution.
- 直观的Micromeritics MicroActive软件将用户定义的报告与可以交互评估等温线数据的能力相结合。用户选择的数据范围通过图形接口允许直接建模,用于BET,T-Plot,Langmuir,DFT解释和新的高级NLDFT方法。
- Up to five different nonreactive adsorptives, plus an additional gas for free space, can be attached to the analyzer simultaneously.
- 伺服压力控制在分析过程中调节剂量和疏散,以减少分析时间。
Sample Preparation System
- The ASAP 2425 system includes twelve automatically controlled sample preparation ports that operate
independently. Samples may be added or removed from degas ports without disturbing the treatment of
other samples undergoing preparation. - The sample preparation system is fully automated with controlled heating time profiles. Temperature
and ramp rate can be set and monitored individually and controlled from a few degrees above ambient
to 450 °C. The temperature hold period may extend past the point when evacuation is completed. - A programmable pressure threshold can suspend the temperature ramp if the outgassing pressure exceeds the limit specified, preventing destructive steaming or other undesired reactions with residual gasses and vapors.
Low Surface Area Measurement (Krypton) and Micropore Options
In addition to the standard ASAP 2425, low surface area krypton and micropore models are available.
Low surface area (krypton) model includes the addition of a 10 mmHg transducer and permits accurate
measurement of very low surface area materials (< 1 m2/g).
The micropore model includes the addition of a 1 mmHg transducer which extends the low pressure measurement capabilities and allows enhanced performance for characterizing microporous materials. The transducer also increases pressure resolution in the range necessary for micropore analysis.
Application
Pharmaceuticals
Surface area and porosity play major roles in the purification, processing, blending, tableting, and packaging of pharmaceutical products as well as their useful shelf life, dissolution rate, and bioavailability.
Ceramics
Surface area and porosity affect the curing and bonding of greenware and influence strength, texture, appearance, and density of finished goods. The surface area of glazes and glass frits affects shrinkage, crazing, and crawling.
Adsorbents
Knowledge of surface area, total pore volume, and pore size distribution is important for quality control of industrial adsorbents and in the development of separation processes. Surface area and porosity characteristics affect the selectivity of an adsorbent.
Activated Carbons
Surface area and porosity must be optimized within narrow ranges to accomplish gasoline vapor recovery in automobiles, solvent recovery in painting operations, or pollution controls in waste-water management.
Carbon Black
The wear lifetime, traction, and performance of tires are related to the surface area of carbon blacks used in their production.
Catalyst
The active surface area and pore structure of catalysts influence production rates. Limiting the pore size allows only molecules of desired sizes to enter and exit, creating a selective catalyst that will produce primarily the desired product.
Paints and Coatings
颜料或填充剂的表面积会影响光泽,质地,颜色,颜色饱和度,亮度,固体含量和膜粘附特性。印刷媒体涂料的孔隙率对于偏移印刷很重要,在这种打印中会影响起泡,墨水的接受性和墨水保持。
弹性推进剂
The burn rate of propellants is a function of surface area. Too high a rate can be dangerous; too low a rate can cause malfunction and inaccuracy.
Medical Implants
Controlling the porosity of artificial bone allows it to imitate real bone that the body will accept and allow tissue to be grown around it.
Electronics
By selecting high surface area material with carefully designed pore networks, manufacturers of super-capacitors can minimize the use of costly raw materials while providing more exposed surface area for storage of charge.
Cosmetics
Surface area is often used by cosmetic manufacturers as a predictor of particle size when agglomeration tendencies of the fine powders make analysis with a particle-sizing instrument difficult.
Aerospace
Surface area and porosity of heat shields and insulating materials affect weight and function.
Geoscience
孔隙率在地下水水文学和石油勘探中很重要,因为它与结构可以包含的流体量以及提取它需要多少精力有关。
Nanotubes
Nanotube surface area and microporosity are used to predict the capacity of a material to store hydrogen.
Fuel Cells
Fuel cell electrodes require high surface area with controlled porosity to produce optimum power density.
Superior Data Presentation Capability
创新的微型软件
微粒学的创新MicroActive软件ows users to interactively evaluate isotherm data. Users can
轻松地包括or exclude data, fitting the desired range of experimentally acquired data points using interactive,
movable calculation bars. Isotherms can be viewed on either a linear or logarithmic scale.

Data Reduction Benefits
- Interaction with adsorption data is direct. By simply moving the calculation bars, the user is immediately updated with new textual properties.
- Interactive data manipulation minimizes the use of dialog boxes and tunneling of dialogs to specify
calculation parameters. - Ability to overlay files (up to 25) including mercury intrusion data with a file add-and-subtract feature.
- 游览器通过图形的数据范围terface allow direct modeling for BET, t-Plot, Langmuir,
DFT interpretation, and much more. - Report Options editor allows the user to define reports with on-screen previews. Information from each
report can be included in a concise summary, as well as in a tabular and graphical information pane.
ASAP 2425 Interactive Reports include (when appropriate to the analysis performed):
- 等温线
- BET Surface Area
- Langmuir Surface Area
- t-Plot
- Alpha-S Method
- BJH Adsorption and Desorption
- Dollimore-Heal的吸附和解吸
- Horvath-Kawazoe
- Saito-Foley
- Cheng-Yang
- MP-Method
- DFT Pore Size and Surface Energy
- Dubinin-Radushkevich
- Dubinin-Astakhov
- NLDFT Advanced Reports
- User-Defined Reports
ASAP 2460 & 2425 Resources
Standard Methods
- ASTM D3908 Standard Test Method for Hydrogen Chemisorption on Supported Platinum Catalysts by Volumetric Vacuum Method
- ASTM D4824 Standard Test Method for Determination of Catalyst Acidity by Ammonia Chemisorption
- WK61828 Carbon Monoxide on Supported Platinum on Alumina Catalysts using Manometric Method
- WK71859使用静态真空法对铝催化剂的支撑铂载碳化学吸附
- ASTM D4780 Standard Test Method for Determination of Low Surface Area of Catalysts and Catalyst Carriers by Multipoint Krypton Adsorption
- ASTM E2864 Standard Test Method for Measurement of Airborne Metal Oxide Nanoparticle Surface Area Concentration in Inhalation Exposure Chambers using Krypton Gas Adsorption
- ISO 15901-3 PORE SIZE DISTRIBUTION AND POROSITY OF SOLID MATERIALS BY MERCURY POROSIMETRY AND GAS ADSORPTION — PART 3: ANALYSIS OF MICROPORES BY GAS ADSORPTION
- ASTM D5604 Standard Test Methods for Precipitated Silica—Surface Area by Single Point B.E.T. Nitrogen Adsorption
- ISO 4652 RUBBER COMPOUNDING INGREDIENTS — CARBON BLACK — DETERMINATION OF SPECIFIC SURFACE AREA BY NITROGEN ADSORPTION METHODS — SINGLE-POINT PROCEDURES
- ISO 9277比表面的测定A OF SOLIDS BY GAS ADSORPTION — BET METHOD
- ASTM B922 Standard Test Method for Metal Powder Specific Surface Area by Physical Adsorption
- ASTM C1069 Standard Test Method for Specific Surface Area of Alumina or Quartz by Nitrogen Adsorption
- ASTM C1274 Standard Test Method for Advanced Ceramic Specific Surface Area by Physical Adsorption
- ASTM D1993 Standard Test Method for Precipitated Silica-Surface Area by Multipoint BET Nitrogen Adsorption
- ASTM D3663催化剂和催化剂载体表面积的标准测试方法
- ASTM D4222 Standard Test Method for Determination of Nitrogen Adsorption and Desorption Isotherms of Catalysts and Catalyst Carriers by Static Volumetric Measurements
- ASTM D4365 Standard Test Method for Determining Micropore Volume and Zeolite Area of a Catalyst
- ASTM D4641 Standard Practice for Calculation of Pore Size Distributions of Catalysts and Catalyst Carriers from Nitrogen Desorption Isotherms
- ASTM D6556 Standard Test Method for Carbon Black—Total and External Surface Area by Nitrogen Adsorption
- ASTM D8325 Standard Guide for Evaluation of Nuclear Graphite Surface Area and Porosity by Gas Adsorption Measurements
- ISO 12800 NUCLEAR FUEL TECHNOLOGY — GUIDELINES ON THE MEASUREMENT OF THE SPECIFIC SURFACE AREA OF URANIUM OXIDE POWDERS BY THE BET METHOD
- ISO 15901-2 PORE SIZE DISTRIBUTION AND POROSITY OF SOLID MATERIALS BY MERCURY POROSIMETRY AND GAS ADSORPTION — PART 2: ANALYSIS OF MESOPORES AND MACROPORES BY GAS ADSORPTION
- ISO 18757 FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) — DETERMINATION OF SPECIFIC SURFACE AREA OF CERAMIC POWDERS BY GAS ADSORPTION USING THE BET METHOD
- ISO 18852 RUBBER COMPOUNDING INGREDIENTS — DETERMINATION OF MULTIPOINT NITROGEN SURFACE AREA (NSA) AND STATISTICAL THICKNESS SURFACE AREA (STSA)
- USP <846> Specific Surface Area
- ASTM C110 Standard Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone